Intel: Please tell me the current limit detection time of OPCth TYP 1.4A of EP53A8LQI.

Power/Enpirion

Category: Power
tool:-
Device: Enpirion®


EP53A8LQI activates OCP immediately when the OCP Threshold (Typ=1.4A, Min=1.25A) is reached.
There is no detection time delay.

Therefore, the rush current must be used at OCP Threshold Min=1.25A or less.
(Recommended Output Current Range is 1000mA or less.)