Analog Devices LTspice: I set the power supply model to AC 1 in AC analysis, but does that mean a sine wave with an amplitude of 1?

LTspice

To be precise, it is set to "set the Small Signal reference used in AC analysis to "1" (0 dB)". So if you say "AC 2", the source power and the reference will be 6dB and the display will also be 6dB higher.

(Published in March 2023)