Analog Devices Design Support: Please tell me how to use thermal resistance ΘJC.

Design support

Thermal resistance ΘJC should be used to estimate junction temperature when using a heat sink. For molded packages, if you measure the case temperature and calculate the junction temperature using the formula "TJ = Tc. + ΘJC x Pd", be aware that the junction temperature will be underestimated.

If you want to know more, please consider attending the Thermal Design Seminar (held once every 2-3 months).

(Published in March 2023)

Please feel free to ask us any questions using the inquiry form.
A person in charge of Analog Devices products will answer your question.

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.