Analog Devices filter: LTC1068's "DC Offset Voltage" VOS2 has MAX.±25mV, but is the distribution of this error the same probability of 5mV and -5mV centering on 0V?

Analog function IC

The error distribution is not symmetrical around 0V.

Since the error is a characteristic at all temperatures, it means that VOS2 has a random error between ±25mV. In general, it is thought that as the IC temperature rises, the error approaches the maximum value (±25mV). The same applies to VOS1 (max±15mV) and VOS3 (max±40mV).