Infoblox
infoblocks
Advanced DNS Protection
model | PT-1405 | PT-2205 | PT-4000 |
System specifications | |||
---|---|---|---|
DNS performance (queries/sec) |
75,000 | 200,000 | 200,000 |
DHCP performance (leases/sec) |
450 | 900 | 1,020 |
database capacity (number of objects) |
880,000 | 3,000,000 | 10,000,000 |
Grid Master use as |
× (used as a member) |
× (used as a member) |
× (used as a member) |
hardware specs | |||
network interface | N/A | N/A | N/A |
N/A | N/A | N/A | |
N/A | N/A | N/A | |
Expansion interface slot *1 | can be 4x1GE: SFP Copper, optical (SX) interface |
can be 4x1GE: SFP Copper, optical (SX) interface 4×10GE: SFP+ optical (SR/LR) interface |
can be 4x1GE: SFP Copper, optical (SX) interface 4×10GE: SFP+ optical (SR/LR) interface |
LOM (Lights Out Management) | 1 x 10/100/1000 Base-T Ethernet (IPMI 2.0 compliant) |
1 x 10/100/1000 Base-T Ethernet (IPMI 2.0 compliant) |
1 x 10/100/1000 Base-T Ethernet (IPMI 2.0 compliant) |
Serial port | DB-9 Male | DB-9 Male | DB-9 Male |
LCD panel | N/A | N/A | N/A |
FAN | 6 | 6 | 6 |
HDD | 1 FRU support *2 |
Four (RAID 10 compatible) FRU compatible *2 |
Four (RAID 10 compatible) FRU compatible *2 |
Power supply specifications | 1 No power redundancy AC power 100-240VAC, 50-60Hz |
2 With power redundancy AC power 100-240VAC, 50-60Hz |
2 With power redundancy AC power 100-120VAC, 200-240VAC, 50-60Hz |
power capacity | 600W | 600W | 750W |
Operating environment | 5 to 35°C (10% to 90% relative humidity, non-condensing) |
5 to 35°C (10% to 90% relative humidity, non-condensing) |
5 to 35°C (10% to 90% relative humidity, non-condensing) |
Storage environment | -40 to 50℃ (10% to 90% relative humidity, non-condensing) |
-40 to 50℃ (10% to 90% relative humidity, non-condensing) |
-30 to 60℃ (10% to 90% relative humidity, non-condensing) |
External dimensions of main unit (H x W x D) | 1U 19 inch rack compatible 44mm x 441mm x 547mm |
2U 19 inch rack compatible 88mm×441mm×547mm |
2U 19 inch rack compatible 87.9mm×445.5mm×698.5mm |
weight | 9.07kg | 13.15kg | 27.2kg |
safety standards | FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, EAC | FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, EAC | FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, EAC |
European Product Environmental Regulations | WEEE, RoHS | WEEE, RoHS | WEEE, RoHS |