Infoblox
infoblocks
Trinzic Reporting
model | TR-805 | TR-1405 | TR-2205 | TR-4000 |
System specifications | ||||
---|---|---|---|---|
Data ingested per day | 2GB | 5GB | 10GB | 20GB |
database capacity (number of objects) |
33,000 | 440,000 | 3,000,000 | 10,000,000 |
Grid Master use as |
× (used as a member) |
× (used as a member) |
× (used as a member) |
× (used as a member) |
hardware specs | ||||
network interface | 2 x 10/100/1000 Base-T Ethernet (LAN port) |
2 x 10/100/1000 Base-T Ethernet (LAN port) |
2 x 10/100/1000 Base-T Ethernet (LAN port) |
2 x 10/100/1000 Base-T Ethernet (LAN port) |
1 x 10/100/1000 Base-T Ethernet (HA port) |
1 x 10/100/1000 Base-T Ethernet (HA port) |
1 x 10/100/1000 Base-T Ethernet (HA port) |
1 x 10/100/1000 Base-T Ethernet (HA port) |
|
1 x 10/100/1000 Base-T Ethernet (MGMT port) |
1 x 10/100/1000 Base-T Ethernet (MGMT port) |
1 x 10/100/1000 Base-T Ethernet (MGMT port) |
1 x 10/100/1000 Base-T Ethernet (MGMT port) |
|
Expansion interface slot *1 | none | can be 4x1GE: SFP Copper, optical (SX) interface 4×10GE: SFP+ optical (SR/LR) interface |
can be 4x1GE: SFP Copper, optical (SX) interface 4×10GE: SFP+ optical (SR/LR) interface |
can be 4x1GE: SFP Copper, optical (SX) interface 4×10GE: SFP+ optical (SR/LR) interface |
LOM (Lights Out Management) | 1 x 10/100 Base-T Ethernet (IPMI 2.0 compliant) |
1 x 10/100/1000 Base-T Ethernet (IPMI 2.0 compliant) |
1 x 10/100/1000 Base-T Ethernet (IPMI 2.0 compliant) |
1 x 10/100/1000 Base-T Ethernet (IPMI 2.0 compliant) |
Serial port | DB-9 Male | DB-9 Male | DB-9 Male | DB-9 Male |
LCD panel | N/A | N/A | N/A | N/A |
FAN | 3 | 6 | 6 | 6 |
HDD | 1 | 1 FRU support *2 |
Four (RAID 10 compatible) FRU compatible *2 |
Four (RAID 10 compatible) FRU compatible *2 |
Power supply specifications | 1 No power redundancy AC power 100-240VAC, 47-63Hz |
1 No power redundancy AC power 100-240VAC, 50-60Hz |
2 With power redundancy AC power 100-240VAC, 50-60Hz |
2 With power redundancy AC power 100-120VAC, 200-240VAC, 50-60Hz |
power capacity | 350W | 600W | 600W | 750W |
Operating environment | 5 to 35°C (10% to 90% relative humidity, non-condensing) |
5 to 35°C (10% to 90% relative humidity, non-condensing) |
5 to 35°C (10% to 90% relative humidity, non-condensing) |
5 to 35°C (10% to 90% relative humidity, non-condensing) |
Storage environment | -40 to 50℃ (10% to 90% relative humidity, non-condensing) |
-40 to 50℃ (10% to 90% relative humidity, non-condensing) |
-40 to 50℃ (10% to 90% relative humidity, non-condensing) |
-30 to 60℃ (10% to 90% relative humidity, non-condensing) |
External dimensions of main unit (H x W x D) | 1U 19 inch rack compatible 44 mm x 441 mm x 522mm |
1U 19 inch rack compatible 44mm x 441mm ×547mm |
2U 19 inch rack compatible 88 mm x 441 mm x 547mm |
2U 19 inch rack compatible 87.9 mm x 445.5 mm x 698.5mm |
weight | 7.71kg | 9.07kg | 13.15kg | 27.2kg |
safety standards | FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, GOST | FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, EAC | FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, EAC | FCC, CE, TUV, CB, VCCI, C-Tick, KCC, CCC, NOM, BIS, EAC |
European Product Environmental Regulations | WEEE, RoHS | WEEE, RoHS | WEEE, RoHS | WEEE, RoHS |
*1 The expansion interface is installed at the factory. Also, existing network interfaces will be unavailable.
*2 Abbreviation for Field Replaceable Unit (Replacement is possible for each failure part.)
Inquiry/Document request
Macnica Infoblox
- TEL:045-476-2010
- E-mail:infoblox-sales@macnica.co.jp