Texas Instruments C2000 Series: What is the code size limit for CLA tasks?
Microcomputer
C2000 series
The upper limit differs depending on the CLA generation.
- 2K instructions - CLA Type 0 part number: TMS320F2803x, etc.
- 64K instructions - CLA Type 1 part number: TMS320F2837xD/S, etc.
- 64K instructions - CLA Type 2 part number: TMS320F280049, etc.
*In Type1 and Type2, the size of RAM that can be allocated to CLA seems to be the real limit.
Related FAQ
- What triggers the CLA to start processing?
- How many clocks does it take for the CLA to respond after detecting a trigger?
- What is the state of CLA after hard reset?
- How many programs (tasks) can be registered with CLA?
- Can multiple CLA tasks be triggered at the same time?
- What are the arbitration rules when multiple CLA tasks conflict?
- Can CLA tasks be nested?
- Is it possible to interrupt from the CLA to the main CPU?
- Can I force CLA tasks off the CPU?
- How are CLA tasks completed?