Part 6: Points to note when selecting an FPGA power supply - Part 1 -

In this sixth installment, we will explain the key points to consider when selecting a power supply for an FPGA, from the perspective of the FPGA's power supply specifications.
This time, as with the previous example, we will continue to use the "Cyclone V (5CSXFC5D)" as our example.

Point 1: Understanding FPGA power supply specifications

First, we will examine the required power supply accuracy of the FPGA by checking the datasheet and pin connection guidelines, and then look at the points to note after correctly understanding the power supply specifications required by the FPGA.

Checking FPGA power specifications

  • Check Power Supply Sharing Guide Lines on Pin Connection Guide Lines to verify voltage and accuracy
  • Check core (VCC, etc.) voltage and voltage accuracy
  • Check the voltage and voltage accuracy of PLL (VCCA_FPLL, etc.)
  • Check IO voltage and voltage accuracy

Point 2: Voltage range and accuracy

Check the actual voltage range and accuracy of various power lines. In our Cyclone V SX case, VCC requires a voltage of 1.1V with a range of ±30mV.

Check the numbers for both units

  • VCC voltage range is 1.07V to 1.13V, ±2.72% fluctuation range when centered at 1.1V
  • The voltage range of VCCA_FPLL is 2.375V to 2.625V, ±5% fluctuation range when centered at 2.5V.
  • IO voltage range is 1.71V to 1.89V, ±5% fluctuation range when centered at 1.8V
<Image 2-1>
<Image 2-2>

Point 3: Select the supply current with a margin for the estimated current value.

(*For EPE, +30% is the default value.)

Point 4: Transient response (transient, PDN specifications)

Apart from point 2, another fluctuation range is specified for sudden voltage fluctuations. Check the Allowable Ripple for each device in the PDN tool's Introduction sheet, as the values vary depending on the device.
(In this case: 5%)

Point 5: Verify the FPGA startup sequence.

Refer to the Power-Up Sequence in the device handbook, as the startup sequence may be specified for each device.

In the case of this example “Cyclone V SX”, the device handbook
Volume1: Device Interfaces and Integration ⇒ Refer to Power Management in Cyclone V Devices

Point 6: Waveform at power startup (monotonic increase)

In the case of this example "Cyclone V SX", it is necessary to raise tRamp in the range of [200usec-100msec] at least.

Cyclone V Device Datasheet
⇒ Page 7 Electrical Characatrize
⇒ Operating Conditions
⇒ Recommended Operating Conditions

<Image 5>
<Image 6>

This time, we have explained "Points to note when selecting an FPGA power supply" starting with the FPGA specifications.

 

Here's an overview of the μModule® used in the Altera evaluation board >>