Symantec products

symantec products

Content Analysis (CA) Specification

hardware specs

*This specification is subject to change without notice. When sizing, please be sure to contact our person in charge.

Content Analysis

S400 series

model

CA S400-A1

CA S400-A2

CA S400-A3

CA S400-A4

System specifications
HDD

2 x 500GB

RAM

16GB

32GB

Network

2-port 1000Base-T (with bypass)

2-port 1000Base-T (no bypass)

Optional NICs

2-port 10G BASE-SR (fiber, with bypass)

Operating environment
Power supply specifications

AC Power 100-127V 8A, 200-240V 4A, 47-63Hz

Maximum power consumption

450 watts

Calorific value

1086 BTU/hr typical, 1381 BTU/hr maximum

temperature

5°C to 40°C (41°F to 104°F)

humidity

20% to 80% relative humidity, non-condensing

Altitude

Up to 3,048 m (10,000 ft)

Main unit external dimensions (L x W x H)

57.2 cm x 43.25 cm x 4.29 cm*1

64.3 cm x 48.54 cm x 4.29 cm*2

weight

12.8kg

Mount method

19 inch rackmount (1U)

Operating environment
electromagnetic wave standards

CISPR22 Class A, CISPR24, FCC part 15 Class A, ICES-003 Class A, EN 55022 Class A, EN55024, EN61000-3-2, EN61000-3-3, VCCI V-3 Class A, BSMI-CNS13438 Class A, CCC-GB9254/GB17625, AS/ZNS-CISPR22, KC-RRA Class A, GOST-R 51318.22 Class A/51318.24/51317.3.2/51317.3.3

safety standards

CB - IEC60950-1 Second Edition, NRTL - UL60950-1 Second Edition, SCC - CSA-22.2 No.60950-1 Second Edition, CE - EN60950-1 Second Edition, NOM-019-SCFI by NRTL Declaration, S Mark - IEC 60950-1, BSMI - CNS-14336-1, CCC - GB4943.1, AS/NZS 60950-1, Second Edition, CU - IEC 60950-1

  • *1 External dimensions (case only)
  • *2 External dimensions (including chassis, handle, and rack mount bracket)

S500 series

model

CA S500-A1

System specifications
HDD

6 x 1TB

RAM

128GB

Network

2-port 10G Base-T (no bypass)

1 port 1000 Base-T (System Management port)

Optional NICs

none

Operating environment
Power supply specifications

AC power 100-240V, 50-60Hz, 12-5A

Maximum power consumption

1100 watts

Calorific value

2598.42 BTU/hr typical, 3751 BTU/hr maximum

temperature

5°C to 40°C (41°F to 104°F)

humidity

20% to 80% relative humidity, non-condensing

Altitude

Up to 3,048 m (10,000 ft)

Main unit external dimensions (L x W x H)

71.0cm×43.33cm×8.72cm*1

81.28 cm x 43.34 cm x 8.72 cm*2

weight

30kg

Mount method

19 inch rackmount (2U)

Operating environment
electromagnetic wave standards

CISPR22 Class A, CISPR24, FCC part 15 Class A, ICES-003 Class A, EN 55022 Class A, EN55024, EN61000-3-2, EN61000-3-3, VCCI V-3 Class A, BSMI-CNS13438 Class A, CCC-GB9254/GB17625, AS/ZNS-CISPR22, KC-RRA Class A, GOST-R 51318.22 Class A/51318.24/51317.3.2/51317.3.3

safety standards

CB - IEC60950-1 Second Edition, NRTL - UL60950-1 Second Edition, SCC - CSA-22.2 No.60950-1 Second Edition, CE - EN60950-1 Second Edition, NOM-019-SCFI by NRTL Declaration, S Mark - IEC 60950-1, BSMI - CNS-14336-1, CCC - GB4943.1, AS/NZS 60950-1, Second Edition, CU - IEC 60950-1

  • *1 External dimensions (case only)
  • *2 External dimensions (including chassis, handle, and rack mount bracket)

Inquiry/Document request

In charge of Macnica Symantec Co., Ltd.

Mon-Fri 8:45-17:30