Forescout

ForeScout

Forescout Platform Specifications

appliance

When used as an analysis sensor (eyeSight, etc.)

model 5120 5140 5160
Performance specifications
number of devices 1,000 5,000 20,000
Number of switches/WLANs 20 100 400
Monitoring band 1 Gbps 5Gbps 10Gbps
hardware specs
10/100/1000BASE-T 4
SFPs 4 (2 x 1G/10G dual rate SR SFP standard included)
HDD 3 HDDs (RAID 1 + hot spare)
Size (H x W x D) 4.28×48.18×70.51cm
Packed size 27.94×62.87×84.18cm
Weight when packed 61 pounds (about 27.67 kg)
power supply 2 x 750W, 100-240VAC (redundant power supply)
Maximum power consumption 744W
Maximum calorific value 2,891 BTU/hr
Temperature (operating environment) 5°C to 40°C
Humidity (operating environment) 10%~80%

* MAC addresses and (or) IP addresses of user devices, NW devices, non-user devices, servers, etc. that Forescout Platform can recognize are counted as the number of devices.

When used as an integrated management server (eyeManage)

model 5120 5140 5160
Performance specifications
appliance
Management number
10 100 200
hardware specs
10/100/1000BASE-T 4
SFPs 4 (2 x 1G/10G dual rate SR SFP standard included)
HDD 3 HDDs (RAID 1 + hot spare)
Size (H x W x D) 4.28×48.18×70.51cm
Packed size 27.94×62.87×84.18cm
Weight when packed 61 pounds (about 27.67 kg)
power supply 2 x 750W, 100-240VAC (redundant power supply)
Maximum power consumption 744W
Maximum calorific value 2,891 BTU/hr
Temperature (operating environment) 5°C to 40°C
Humidity (operating environment) 10%~80%

License type

eyeSight eye control eye extend eye segment eyeRecover
role
  • detection
  • classification
  • evaluation
  • notification
    E-mail notification
  • notification
    HTTP redirect
  • Remediation/Control
    Virtual FireWall
    ACL control
  • Remediation/Control
    Cooperation with existing security tools
  • operation
    Cooperation with existing security tools
  • simulation
  • segmentation
  • Redundant configuration
  • Cluster configuration
type 1 type 25 types
By linked product
1 type
Form of provision
  • Perpetual license
  • Subscription license (3 year lump sum only)
price
range
Number of management IP addresses: 100 x N (N = number of licenses)

* About eyeManage (integrated management, Enterprise Manager)
The eyeManage license is provided free of charge to license purchasers. However, you will need to purchase the 5100 series separately as hardware.
As a general rule, we recommend making eyeManage redundant.

Information needed for sizing

Information required to determine the number of licenses and configuration

  • Number of terminals managed (visualized and controlled) by Forescout
    1. *Terminal here means "thing that Forescout identifies by MAC address or IP address, or both information". Therefore, terminals with multiple MAC/IP addresses, such as terminals with multiple NICs, may be counted for that number.
  • Type of license used (e.g. eyeSight, eyeControl, etc.)

Information needed for appliance sizing

  • Total number of devices to manage
  • Total number of linked switches/access points
  • Traffic to be monitored (Gbps): Only when analyzing communication from the mirror port