Texas Instruments LMK03328: How do I use CodeLoader?
Please follow the steps below.
procedure
1. Download the CodeLoader provided by TI for register programming from the link below.
http://www.ti.com/tool/CODELOADER
2. Start CodeLoader and select LMK03328 from "Select Device" → "Clock Conditioners".
3. Enter various setting values based on setting information simulated based on WEBENCH or design information considered on paper.
4. Just in case, select “Keyboard Controls” → “Load Device”.
5. VCO Calibration is required after register setting.
Go to the "Inputs/PLLs" tab,
Check RESETN_SW ON → OFF → ON. The above gives the output.
The frequency calculated for "OUTx" on the "Outputs" tab is calculated based on the "PRIREF" frequency on the "Inputs/PLLs" tab. Be sure to manually enter the correct PRIREF frequency.
Experienced FAE
Free consultation is available.
From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.