Texas Instruments LDC1312: What is the sensor dependent delay time when an inductive sensor detects motion? (time required for the value to be determined)

sensor

After the input waveform stabilizes, for example, if 13 bits of data are required, 2^13=8192 clocks are required, and that much delay occurs.

See the datasheet for details.
URL: http://www.tij.co.jp/general/jp/docs/lit/getliterature.tsp?baseLiteratureNumber=snoscz0&fileType=pdf

Applicable part: P13
if an ENOB of 13 bits is required, then a minimum conversion time of 2^13 = 8192 clock cycles is
8192 clock cycles corresponds to a CHx_RCOUNT value of 0x0200.

*Please note that chapters and drawing numbers may change when the datasheet is updated to a new revision.

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.