Please tell me how to read the specifications of CrossLink LVDS (7:1). There are two notations, UI and ns+(i+1/2)*UI, in the datasheet. What is the difference?

CrossLink Series

カテゴリー : -
ツール : -
デバイス : CrossLink


If the frequency is the maximum value of ECLK (fMAX_RX71_141 = 450MHz) and i=0, the two notations match.

Calculate specifically. At 450MHz, 1UI = 1 / (450MHz x 2) = 1.11 ns.
For tPRBi_DVA, the upper row is 0.3UI = 0.333ns. Assuming i=0 in the lower row,
-0.222 + (0 + 1/2) x UI = -0.222 + 1/2 x 1.11 = 0.333ns
and are equal. Similarly for tPRBi_DVE
Top: 0.7UI = 0.777ns, Bottom: 0.222 + (0 + 1/2) x UI = 0.222 + 1/2 x 1.11 = 0.777ns
and both give the same result.

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.