In the Hierarchy window of Project Navigator, even if you click the schematic-designed Entity in the lower hierarchy, the file cannot be opened. Files can be opened when selected from the Files tab or the Design Units tab.

<error message>
Can't find design entity "***"




A problem has been identified with the "cross probing" function that jumps to the schematic in the display part of the Hierarchy tab.

In the actual compilation, it is recognized as a design, so there is no problem.

Please be careful when opening the file.

Quartuas II versions that we have confirmed that this problem occurs: 11.1, 11.1SP1, 11.1SP2