Please tell me how to create data for writing hardware and software images to EPCS devices.

Use Convert Programming File to generate write data.

The operation is described below.

Click Convert programming File in the File menu
Set the programming file type to Programmer Object File (.pof) or JTAG Indirect Configuration File (.jic) when programming with JTAG Indirect
Select EPCS16 or EPCS64 for Configuration device :
Set any output file name in File name
Highlight SOF Data and select ***.sof in Add File
Highlight SOF Data and click Properties.
Select Start in "Address mode for select pages" and set Start Address to "0x0"
Click Add hex Data, select Relative addressing in Addressing mode, and specify Hex File
(Do not check Set start address when selecting Relative addressing)
Click Generate to generate the JIC/POF (Check ***.map, the software image is stored from the address just after the hardware image)


Please follow the steps above to check.

Refer to 1 to 3 in the URL below to generate the HEX data of the software image used in Convert programming File.
 https://www.altera.co.jp/support/support-resources/knowledge-base/solutions/rd10132010_126.html