In the DC characteristics listed in the Device Handbook, does the recommended operating range include the allowable ripple voltage range?
Power/Enpirion
No, the device's recommended operating range conditions refer to DC values with no variation.
The recommended allowable ripple means AC transient voltage fluctuation, so please check with the Power Distribution Network (PDN) tool.
Please refer to the URL that describes the PDN below.
https://www.altera.com/support/support-resources/support-centers/signal-power-integrity/power-distri...
Experienced FAE
Free consultation is available.
From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.