Is word (byte) alignment automatic when doing a high speed LVDS interface with Dynamic Phase Alignment (DPA)?

IP

No, it doesn't happen automatically.

When DPA is used and the same state as the parallel data train of the transmitted data is restored on the receiving side, it is necessary to independently perform word (byte) alignment using the bit slip function or user logic.

Experienced FAE