Site Search

There are cases where TCCS (Transmitter channel-to-channel skew) for each I/O Standard is not described in the handbook. Is there a way to find out?

Timing constraints/analysis

TCCS is Quartus II and can be found in the compilation report if the TimeQuest Timing Analyzer is selected.

If you already have a design, try compiling it.

The confirmation method is from the compilation report,
Compilation Report ⇒ TimeQuest Timing Analyzer ⇒ Report TCCS

Experienced FAE
Free consultation is available.