Intel: What are the power-up time requirements for using Active Serial Fast Mode on Stratix® 10?

board

Category: Board
tool:-
Device: Stratix® 10

Group 1 to 3 power supplies must reach the specified value within 10ms in total.

(Reference) Intel® Stratix® 10 Device Datasheet
https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/hb/stratix-10/s10_datasheet.pdf
(See Recommended Operating Conditions for Intel Stratix 10 Devices table)

To support AS fast mode, all power supplies to the Intel Stratix 10 device must be fully ramped-up within 10 ms to the recommended operating conditions.

 

For the power sequence, refer to the following document.
(Reference) Intel® Stratix® 10 Power Management User Guide
https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/hb/stratix-10/ug-s10-pwr.pdf