Intel: I'm using the Transceiver PHY IP on Stratix® 10 and I get an error in the Fitter when I set VOD in QSF. Is it not possible to set Analog Parameters in QSF?

Quartus Prime Stratix Transceivers

Category: Walkie Talkie
Tools: Quartus® Prime
Device: Stratix® 10

<Error message>
Error(15653): The Fitter cannot find a legal configuration for the following atoms. Update any outdated transceiver PHY IP cores, correct any illegal pin assignments, and then recompile your design.

This Error occurs in v18.1 Pro issue.
For example, if you want to set VOD to "30", add the following constraint.

set_instance_assignment -name HSSI_PARAMETER "pma_tx_buf_vod_output_swing_ctrl = 30" -to "<tx_serial_data>"
set_instance_assignment -name HSSI_PARAMETER "pma_tx_buf_powermode_ac_tx_vod_w_jitcomp = TX_VOD_W_JITCOMP_AC_L30" -to "<tx_serial_data>"
set_instance_assignment -name HSSI_PARAMETER "pma_tx_buf_powermode_dc_tx_vod_w_jitcomp = TX_VOD_W_JITCOMP_DC_L30" -to "<tx_serial_data>"

(参考)Error(15653): The Fitter cannot find a legal configuration for the following atoms. Update any outdated transceiver PHY IP cores, correct any illegal pin assignments, and then recompile your design.
https://www.intel.com/content/altera-www/global/en_us/index/support/support-resources/knowledge-base/hsio/2019/error-15653---the-fitter-cannot-find-a-legal-configuration-for-t.html

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.