Intel: Arria® 10 devices failed to configure in AS mode and lost JTAG access.

Arria configuration/programming

Category: Configuration/Programming
tool:-
Device: Arria® 10

Performing AS configuration with corrupted or incorrect configuration data on Arria® 10 can leave the device in an unexpected state and disable JTAG access.
To recover from this state, you must issue a CONFIG_IO instruction to the Arria® 10 device to stop the AS configuration process and enable the JTAG port.

Please refer to the following Knowledge Database for a Jam STAPLE file that issues a CONFIG_IO instruction and an execution example.

(参考)Why can't I access the Arria 10 device through the JTAG interface when using Active Serial configuration mode?
https://www.intel.com/content/www/us/en/programmable/support/support-resources/knowledge-base/solutions/rd02282016_156.html