Intel: Depending on the ambient temperature, the initialization time (CONF_DONE is high to INIT_DONE is high) takes tens of ms or more. Does temperature make it this long?

Cyclone configuration/programming

Category: Programming/Configuration
tool:-
Device: Cyclone® V


It doesn't take much longer depending on the temperature.
The INIT_DONE pin requires an external pull-up, but if there is no pull-up or the resistor fails, the time it takes for INIT_DONE to go high can appear long.

Experienced FAE
Free consultation is available.