Site Search

Intel: Use the MAX® 10 remote update feature. If there is a rewrite failure while rewriting the Application Image, is there a way to detect the error?

MAX IP

Category: Quartus® Prime
Tools: Quartus® Prime
Device: MAX®10


You can access the register of the MAX® 10 Dual Configuration IP and check if the update was successful.

Reference information
https://www.altera.com/en_US/pdfs/literature/hb/max-10/ug_m10_config.pdf
(Item of Altera Dual Configuration IP Core Avalon-MM Address Map)

It can be determined by reading the value of busy flag at offset 3 and msm_cs at offset 4 in the register map in the document below.


Experienced FAE
Free consultation is available.