Site Search

Intel: I'm inputting 1.03V for VCCR_GXB and VCCT_GXB on Arria® 10, but the Fitter Report shows 0.95V. where can i change the settings?

Arria Quartus Prime

Category: Specifications
Tools: Quartus® Prime
Device: Arria® 10


Settings can be made in the Pin Planner or Assignment Editor.
In either case, recompile after setting and confirm that it is 1.03V on the Fitter Report.

■ For Pin Planner

  1. Right-click a blank area in the All Pins list and select Customized Columns
  2. Select VCCR_GXB/VCCT_GXB Voltage from Available Columns and click the > button
  3. Make sure it is added to the All Pins list and select the transceiver pin voltage you want to change (0.9=0.95V, 1.0=1.05V, 1.1=1.12V)


■ For Assignment Editor

  1. Register the corresponding XCVR pin name in the To column
  2. Select VCCR_GXB/VCCT_GXB Voltage in the Assignment Name field
  3. Select the appropriate XCVR pin voltage (0.9=0.95V, 1.0=1.05V, 1.1=1.12V)

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.