Intel: Cyclone® V IBIS model description and model characteristics are different.
(description in the IBIS file)
p0—pre-emphasis disabled
p1—pre-emphasis enabled
(Characteristics of IBIS files)
p0—pre-emphasis enabled
p1—pre-emphasis disabled
*The characteristics that can be confirmed in the explanation and the simulation are reversed.
Category: Other
tool:-
Device: Cyclone® V
The pre-emphasis of the IBIS Models uploaded on the web and the IBIS Models created by Quartus® Prime 16.0 is the opposite of the explanation.
Therefore, when using, swap p0 and p1.
This issue has been fixed in Quartus® Prime 16.1, but the IBIS Models posted on the web will be fixed in a future version of Quartus® Prime.
Reference information
https://www.altera.com/support/support-resources/download/board-layout-test/ibis/ibs-ibis_index.html