Does the Exposed Pad on the underside of the MAX® 10 EQFP144 package require any connections?

MAX

Category: Specifications
tool:-
Device: MAX®10


The MAX® 10 EQFP144 package Exposed Pad must be connected to GND.

Pin-Out Files for Intel FPGA Devices (MAX® 10)
https://www.intel.com/content/www/us/en/programmable/support/literature/lit-dp.html#max-10

The documentation for each MAX 10 device with the EQFP144 (E144) package has the following note:
The E144-pin package has an exposed ground pad at the bottom of the package.

MAX 10 Schematic Review Worksheet
https://www.intel.com/content/www/us/en/programmable/support/support-resources/download/board-layout-test/schematic-review-ws.html

In Section I: GND of Power, there is the following description in the Connection Guidelines column.
For the 144 pin EQFP package, the exposed ground pad at the bottom of the package is used for electrical connectivity and must be connected to GND.

Experienced FAE
Free consultation is available.