I would like to use the profile function in Altera SDK for OpenCL v15.0, but I do not know how to use it. Could you tell me how to start and use the profiler?
Category: OpenCL™
tool:-
device:-
As shown in the example below, if you run aocx generated by specifying profile when compiling on a real machine, a file called profile.mon will be generated.
C:\altera\OpenCL\report-test>aoc --profile --report -v double_add_1.cl -o double_add_1.aocx --board s5phq_d8
Specify the executed aocx and the generated profile.mon with the aocl report command to start the Profiler GUI.
$ aocl report double_add_1.aocx profile.mon