There are two slew rate values for the ENABLE pin of the EN2342QI device. What's the difference?
Power/Enpirion
Category: Power
tool:-
Device: Enpirion®
The required minimum slew rate varies depending on whether the Pre-Bias function is used or not.
When using Pre-Bias: 3V/100us or more
When not using Pre-Bias: 1V/100us or more
For details, refer to the document below.
https://www.altera.com/en_US/pdfs/literature/ds/en2342qi_09520.pdf
(Search with the keywords "Enable Operation" and "Pre-Bias Operation".)