Analog Devices AD Converter: Utilizes the AD7172-2 in single conversion mode. Please tell me the operation from writing the conversion start command (to register 0X01) to the first data output (issue /RDY signal pulse).

A/D converter (ADC)

The operation after writing the conversion start to the register is as follows.
 
(1) Delay time set for startup
(2) Settling time (reset the internal digital filter. 1/MCLK x 64 x 5 = 160 μS)
(3) If the data rate is 2.6Ksps or more with the Sinc5 + Sinc1 filter, the time is 1/data rate x 5,
Sinc5 + Sinc1 filter, if data rate is 2.6Ksps or less, 1/data rate time,
Sinc3 filter issues /RDY signal pulse after 1/data rate x 3 time
 
* Sinc5 + Sinc1 filter: Acquire data 5 times at 31.25Ksps and process the moving average filter. If the output data rate is less than 2.6Ksps, then adjust the data rate and output.
 
*Sinc3 : Moving average filter using 3 times data


(Published in March 2022)

Please feel free to ask us any questions using the inquiry form.
The person in charge of Analog Devices products will answer your question.

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.