Analog Devices power measurement IC: ADE78XXA is described in the datasheet as being compliant with the IEC62053-22 standard, but how can it be compliant with the accuracy standard class 0.1s, 0.2s, 0.5s, etc.?

A/D converter (ADC)

Although it is not necessarily required, the configuration assumed by the manufacturer is as follows.
In the case of 0.5s (standard class), a configuration using the ADE78XXA internal reference can be used.
For 0.2s/0.1s, it is recommended to use a precision external reference when using the ADE78XXA. Appropriate accuracy selection is also required for current and voltage sensors and crystals. If the IC internal reference is used, we recommend choosing ADE9000 or ADE9078.


(Published in March 2022)

Please feel free to ask us any questions using the inquiry form.
The person in charge of Analog Devices products will answer your question.

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.