Analog Devices Battery Charger: Does the LTC4040 trickle charge the battery even if it is deeply discharged?

power management

A preconditioning (trickle charge) phase is also triggered in case of an abnormally over-discharged battery.
Within 0.5H of this preconditioning, if the voltage rises above the default 2.85V, the battery is determined to be rechargeable and the proper charge cycle is initiated.

(Published in March 2022)