Site Search

Analog Devices RF Active Mixers: On the LT5560, when operating the LO input single-ended, should the input come from LO- or LO+?

RF and microwave

The LO input can be driven with a single-ended source for both low-side and high-side LO operation.

(Published in November 2021)

If the problem persists

Please feel free to ask us any questions using the inquiry form.
The person in charge of Analog Devices products will answer your question.

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.