Site Search

Analog Devices Digital Potentiometers : What should I be aware of when using the AD5292 in parallel?

D/A converter (DAC)

The AD5292's SDO pin is not synchronized with /SYNC. Therefore, when connecting in parallel, it is recommended to set SDO to Hi-Z each time communication with one AD5292 is completed.

If the problem persists

Please feel free to ask us any questions using the inquiry form.
The person in charge of Analog Devices products will answer your question.

Experienced FAE
Free consultation is available.

From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.