What is the difference between Weak Pull-Up Resistor and Passive Resistor (Pull-Up or Pull-Down) settings?
You can select the respective constraints within the Assignment Name in Quartus II / Quartus Prime.
A weak pull-up resistor pulls the device's terminals high using an internal pull-up resistor.
The Passive Resistor is a virtual resistor used only in Function Simulation. Therefore, it allows for pull-down settings that are not supported by Altera FPGAs.