Altera: It's generally said that reducing the clock frequency by dividing it using a PLL increases jitter. Could you explain why?
Category: Specifications
tool:-
device:-
PLL jitter generally varies depending on the number of post-scaler stages.
In a PLL, clock frequency division is performed using a post-scaler located after the VCO.
When the postscaler setting is large, the number of register stages in the postscaler also increases, but when the postscaler setting is small, the number of register stages in the postscaler also decreases.
It is said that the jitter increases because the inherent internal jitter (delay variation) of each register accumulates over time, depending on the number of register stages.
For example, if you divide the input clock by 2 (half the original frequency), the post-scaler set to a value of 2 will consist of one register.
When the input clock is divided by 8 (1/8th), the post-scaler, set to a value of 8, consists of 3 registers.
In this case, the total internal jitter of the three registers will inevitably be greater than that of the single register.
Therefore, a clock obtained by dividing the input clock by 8 will have more jitter than a clock obtained by dividing it by 2.
If you want to maximize the impact of jitter, and if there is sufficient space on the circuit board and a sufficient number of components, it is ideal to use a PLL (Jitter Cleaner or Jitter Attenuator) specifically designed to reduce jitter.
Experienced FAE
Free consultation is available.
From specific product specifications to parts selection, the Company FAE will answer your technical concerns free of charge. Please feel free to contact us.