This article introduces Analog Devices' biopotential AFE (analog front end).

The AD8233 biopotential AFE is an integrated signal conditioning block for unipolar lead electrocardiogram (ECG) and other biopotential measurement applications, designed to extract, amplify, and filter small biopotential signals under noisy conditions such as those caused by motion or remote electrode placement. This design allows the output signal to be easily acquired by an ultra-low power analog-to-digital converter (ADC) or an embedded microcontroller.

Article header library 125681 pic01 1
Evaluation board: AD8233CB-EBZ

Normally, ECG front-ends need to be designed with discrete components, which is costly and time-consuming. The AD8233 introduced here can reduce unnecessary costs and design time, and shorten the development time for end products.

In addition, the AD8233's small size of 2.0 mm x 1.7 mm enables the design of small and lightweight wearable medical devices that are easy to wear. In addition, long operating life is also a crucial factor for cardiac monitors, and low power consumption is required to ensure continuous monitoring and obtain accurate data without interruption for recharging or battery replacement. The AD8233 is an AFE that achieves low power consumption, which can significantly improve the operating life of products.

Improved device performance from AD8232

Main features and functions of AD8233

  • Integrates all analog circuitry for precise conditioning of biopotential signals from two electrodes
  • System-level performance optimization (fast restore, lead-off, shutdown)
  • Right leg drive circuit (optional)


The AD8233 is the successor to the AD8232 and offers improved device performance compared to the AD8232. The improved comparison is shown in the table below.

specification AD8232 AD8233
Supply Current @ 27℃ 170uA 50uA
Peak to Peak Voltage Noise
(f=0.5Hz to 40Hz)
14uV pp 8.5uV pp
Leads On/Off Detection
in shutdown
Not included Included
Right Leg Drive Shutdown Not included Included
Package size 4mm x 4mm x 0.75 2mm x 1.7mm x 0.5mm

Assumed target application

  • Fitness, exercise heart rate monitoring
  • portableECG
  • Wearable remote health monitor
  • Peripherals for game consoles
  • Biopotential signal acquisition
Article header library 125681 pic02 2
Assumed target application