Mentor: DDRx Batch Wizard no longer has "Simulate loss" setting in HyperLynx VX2.5 and later, where can I set it?

simulation

Category: Other Tools
Tools: HyperLynx® SI
device:-

Please set Simulation Loss in HyperLynx Setup > Enable Lossy Simulation.
This setting is enabled by default, but in the case of HyperLynx, the setting at the time of termination is saved in bsw.ini in the installation directory, and the next time it starts, bsw.ini is read and started, so it depends on the setting at the time of the previous termination. increase.

Experienced FAE
Free consultation is available.